홈 • Life Sciences and Research Solutions • Educational Resources • How to Guides • 4 Tips for Buying a Microtome RELATED CONTENT Buying a Research Microtome: Why Quality Matters in Research Microtomy Leica Biosystems Research Microtome Comparison Guide Tips & Tricks to Better Histology in Tissue-Based Research (Part 2): A Review of Factors Influencing the Quality of Sections 4 Tips for Buying a Microtome What should you look for when purchasing a microtome? Here, we offer 4 tips that will help you through the process. These tips are meant to be a helpful reminder of important considerations when making a purchasing decision. TIP 1: Safety and Ergonomics Image Keeping your lab staff safe is always of utmost importance. Especially when handling sharp blades, microtome users are at risk of cutting themselves. While one might expect that most cutting injuries occur during sectioning, we interviewed over 100 histology professionals to find out what they think. According to their responses, the highest risk for microtomy-related injuries comes from forgetting the blade when cleaning the microtome, followed by handling or exchanging the block and removing the blade. But that’s not all. Many hours of repetitive arm movements with the hand wheel might cause discomfort and increase the risk of developing work-related muscosceletal disorders. To minimize possible microtomy-related injuries, look out for a microtome that addresses these concerns by offering a majority of the following features: Safety locks on the handwheel prevent the object head from moving, thus enabling the user to exchange specimens or blades, as well as adjusting the specimen orientation. An object head which can be adjusted dependent on the object clamp size and weight, prevents it from accidentally dropping on the blade while sectioning quickly. A safety guard covers the blade while the microtome is not being used. That enables the user to clean the microtome or exchange blocks without touching the blade. A blade ejector and magnetic brush help to remove the blade from the blade holder without touching it. An ergonomically designed microtome gives users the option to adjust the microtome to personal preferences, such as a customizable coarse feed wheel, helping to reduce strain on the shoulder. If your lab staff prefers a manual coarse feed wheel for rock trimming, make sure that it is as close to the user as possible, to allow prolonged ergonomic comfort. For improved safety and ergonomic features, consider a motorized rotary microtome: A fully-automated microtome eliminates the need to spin the hand wheel by hand, thus minimizing microtomy-related muscosceletal disorders. An emergency stop button on the instrument housing or foot switch immediately stops the motor in case of an emergency. To prevent the microtome from starting uncontrolled motorized sectioning, the microtome should have a built-in safety mechanism, e.g. two separate buttons need to be pressed to start sectioning. The hand wheel handle of motorized rotary microtomes can be centered to help avoid getting caught when the wheel turns. A fully-automated microtome eliminates the need to spin the hand wheel by hand, thus minimizing microtomy-related muscosceletal disorders. TIP 2: Good Section Quality is Crucial for Patient Care Image Because you are entrusted with human tissue, quality always comes first. When cutting sections from patient tissue, every section counts. High quality sections are a result of multiple factors: precision, stability and quality of the individual components, including the following: The precision of the feeding mechanism. The stability of the microtome to ensure vibration-free sectioning. Quality of the components e.g. blade and knife holders, specimen clamps and associated consumables (blades). A precise specimen-orientation with zero-point reference allows for rapid aligning of the block and is ideal for re-cuts. Using an optional electric specimen cooling device results in uniform section quality as the result of controlled specimen temperature. TIP 3: Reliability / Brand Reputation of the Product Image Ask yourself the following questions to narrow down your choices: Should I consider buying a used microtome? Buying a new microtome provides peace of mind, knowing the equipment has no prior history. Buying from a used equipment supplier bears the risk that the product has not been updated according to the guidelines of the manufacturer and thus does not work properly. Buying factory-refurbished equipment ensures that the instruments have been updated with original spare parts by trained personnel with factory warranty. What are your peers saying? Seek out others that use microtomes and find out what works and what doesn’t. This includes site visits, customer product reviews, blogs, etc. This will help you gain the perspective needed for a decision in your lab. Which companies/products are recognized as reliable in the industry? Consider how long a company has been in the industry. More importantly, does the manufacturer have a high level of customer service at their command to ensure you are supported throughout the entire process? Beginning from sales, to delivery and installation, as well as after sales support. TIP 4: Maintenance and Service Image A microtome is built to last, but when a service call is required, ensure that it is serviced appropriately by the manufacturer. Confirm there are manufacturer-compliant and qualified engineers available to repair the microtome to extend its useful life. Ensure the appropriate parts are available to service the instrument according to factory settings. Many third-party service providers may not have access to parts, and/or may not have immediate availability to parts, which can lead to downtime, ultimately affecting turnaround time and patient care. Related Content Buying a Research Microtome: Why Quality Matters in Research Microtomy Leica Biosystems Research Microtome Comparison Guide Tips & Tricks to Better Histology in Tissue-Based Research (Part 2): A Review of Factors Influencing the Quality of Sections Leica Biosystems 콘텐츠는 Leica Biosystems 웹사이트 이용 약관의 적용을 받으며, 이용 약관은 다음에서 확인할 수 있습니다. 법적고지. 라이카 바이오시스템즈 웨비나, 교육 프레젠테이션 및 관련 자료는 특별 주제 관련 일반 정보를 제공하지만 의료, 규정 또는 법률 상담으로 제공되지 않으며 해석되어서는 안 됩니다. 관점과 의견은 발표자/저자의 개인 관점과 의견이며 라이카 바이오시스템즈, 그 직원 또는 대행사의 관점이나 의견을 나타내거나 반영하지 않습니다. 제3자 자원 또는 콘텐츠에 대한 액세스를 제공하는 콘텐츠에 포함된 모든 링크는 오직 편의를 위해 제공됩니다. 모든 제품 사용에 다양한 제품 및 장치의 제품 정보 가이드, 부속 문서 및 작동 설명서를 참조해야 합니다. Copyright © 2024 Leica Biosystems division of Leica Microsystems, Inc. and its Leica Biosystems affiliates. All rights reserved. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH. Contact Our Product Expert Now If you have viewed this educational webinar or training and would like to apply for continuing education credits with your certifying organization, please download the form to assist you in adding self-reported educational credits to your transcript. 자가보고식 교육학점을 신청 하세요 Subscribe to our mailing list to learn about our upcoming symposiums and new research-focused product launches. 지금 구독하세요! SHARE Facebook Twitter LinkedIn Email