Image Image Image Image Image HistoCore PEGASUS Plus Tissue Processor 14048858007 Gain high confidence in your results Give every tissue type and size the treatment it deserves. Establish a workflow that meets the demands of your laboratory without compromises on tissue quality. The HistoCore PEGASUS Plus tissue processor enables you to run multiple protocols in parallel on a single instrument, ensuring optimal conditions for all tissue types without slowing down your laboratory. Combined with the ability to capture each cassette individually, including cassette ID, quantity and color, as well as basket ID, user ID and reagent information, the HistoCore PEGASUS Plus offers you a fully integrated solution. Contact us to get a quote. Call 400 000 2910 to speak with a representative. For In-Vitro Diagnostic Use Features Specifications Downloads Product Features Don’t Compromise On Tissue Quality Biopsies, large, or fatty specimens; different tissues need different treatments. The HistoCore PEGASUS Plus tissue processor gives you the flexibility to run parallel protocols on a single instrument. Process up to 400 samples simultaneously, increasing your capacity by 33% per run compared to a typical 300 cassettes single-retort tissue processor. Image TRACK. TRACE. CAPTURE. 100% of your cassettes. Capture and record critical data with built-in track & trace features. The integrated iScan technology tracks basket ID, user ID, and reagent information. An optical scanner captures cassette ID, quantity and color, enabling you to trace each sample in the tissue processing workflow. Easy access to the recorded data gives you control over your tissue processing reports while minimizing manual documentation, maximizing confidence. Image Reagent Monitoring Helps Protecting The Tissue A built-in density meter monitors reagent changes and alerts users if it detects an incorrect concentration to protect the integrity of the tissue. Image Reagent Management Made Easy Bar-coded reagents automatically create reagent exchange reports on the tissue processor, recording the lot number, reagent type and concentration of Leica reagents. Image Optimize Your Workflow with Leica Paraffin Use Leica Paraffin with your HistoCore Pegasus Plus tissue processor to further improve your workflow. PEGASUS Parablock paraffin melts 22% faster than pellets. Additionally, you get: No Spills – solid blocks prevent spills from messy pellets Easy Loading – Pegasus Parablocks X-tra™ create a smart safe and easy-to-handle paraffin-related workflow Walk Away – load 4-blocks into Pegasus chambers and walk away. No need to top off paraffin. Image Maximize Your Processing with ActivFlo Cassettes Efficient Reagent Flow - Leica developed “Fluidic Flow” lateral vent and pore design maximizes reagent exchange System Performance - ActivFlo Routine, Biopsy and Mini Biopsy cassettes are validated on Leica tissue processors Easy Snap - Frangible hinge for lid removal Effortless Loading - Stacked and taped configuration allows for quick and easy printer set up Available in 11 colors Image Preferred tissue processing reagents Our preferred tissue processing reagents will help you take the tissue through your preanalytical workflow stages. Broad product offering: Alcohols, Solvents, and Fixatives available in multiple packaging options Reduce Errors: Color-coded labeling simplifies visualization of reagents and reduces reagent mix-ups Track & Trace capability: Bar-coded reagents help record the lot number, reagent type, concentration, and create reagent exchange reports Greener alternatives: Process Tissue with Safer Reagents alternatives by substituting xylene with Sub-X or Clearene. Or switch to xylene-free processing with isopropanol (IPA). Image Product Specifications OPERATING Dimensions (W x D x H): 804 x 715 x 1533 mm Weight (Instrument Only): 235 kg Weight (Including Reagents): 315 kg Number of reagent containers: 17 reagent bottles, 1 condensate bottle Maximum bottle volume: Max. 3.88 L Number of paraffin baths: 4 Capacity: Max. 3.9 L per paraffin bath Melting time: max. 7 hours an ambient temperature of 23°C-25°C Temperature settings range: Paraffin Melting Point setting: 50°C-65°C Standby temperature setting: Paraffin Melting Point +1°C and max. 71°C Capacity: max. 2x200 cassettes Temperature (paraffin): Paraffin temperature selectable from 58°C to 85°C Temperature (processing reagents): Ambient temperature or 35°C-65°C Temperature (cleaning reagents): 35°C -85°C Filling vacuum: -60 kPa Draining pressure: 45 kPa ELECTRICAL Operating Voltage: 100-120VAC/220-240VAC Mains Frequency: 50/60Hz Power Consumption: 100-120VAC 15A Max; 220-240VAC 10A Max Local/remote alarm relay: 30V DC, maximum 1A Documents Brochure Brochure - HistoCore PEGASUS Plus - DE 201346 Rev C Size: 8.73 MB, Type: pdf Brochure - HistoCore PEGASUS Plus - ES 201346 Rev C Size: 764.29 KB, Type: pdf Brochure - HistoCore PEGASUS Plus - EN 201346 Rev C Size: 759.14 KB, Type: pdf Brochure - HistoCore PEGASUS Plus - TR 201346 Rev C Size: 5.76 MB, Type: pdf Brochure - HistoCore PEGASUS Plus - FR 201346 Rev C Size: 5.77 MB, Type: pdf Brochure - HistoCore PEGASUS Plus - IT 201346 Rev C Size: 5.77 MB, Type: pdf Brochure - HistoCore PEGASUS Plus - PT 201346 Rev C Size: 5.77 MB, Type: pdf Brochure - HistoCore PEGASUS Plus - ZH 201346 Rev C Size: 970.19 KB, Type: pdf Brochure - HistoCore PEGASUS Plus - JP 201346 Rev C Size: 5.84 MB, Type: pdf Brochure - HistoCore PEGASUS Plus - KO 201346 Rev C Size: 5.88 MB, Type: pdf Certificate DoC HistoCore PEGASUS Plus D Size: 401.79 KB, Type: pdf Technical Specifications Technical Specifications - HistoCore PEGASUS Plus - EN 211143 Rev D Size: 890.16 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - DE 211143 Rev D Size: 891.53 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - ES 211143 Rev D Size: 889.1 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - FR 211143 Rev D Size: 888.95 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - IT 211143 Rev D Size: 891.08 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - PT 211143 Rev D Size: 889.65 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - JP 211143 Rev D Size: 911.41 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - KO 211143 Rev D Size: 899.69 KB, Type: pdf Technical Specifications - HistoCore PEGASUS Plus - TR 211143 Rev D Size: 744.74 KB, Type: pdf IFU HistoCore PEGASUS Plus IFU 1v5I bg Size: 4.95 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I cs Size: 4.92 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I da Size: 5.53 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I lt Size: 5.58 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I de Size: 5.59 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I el Size: 5.68 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I en Size: 5.54 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I es Size: 5.58 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I fi Size: 5.53 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I fr Size: 5.69 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I hu Size: 5 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I it Size: 5.58 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I ja Size: 5.85 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I kk Size: 4.94 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I ko Size: 5.79 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I nl Size: 5.58 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I no Size: 5.61 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I pl Size: 4.95 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I pt Size: 5.63 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I ro Size: 5.63 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I ru Size: 5.67 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I sk Size: 4.93 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I sr Size: 4.9 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I sv Size: 5.55 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I tr Size: 5.54 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I uk Size: 4.98 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I vi Size: 4.89 MB, Type: pdf HistoCore PEGASUS Plus IFU 1v5I zh Size: 5.91 MB, Type: pdf Education Webinars (Knowledge Pathway)Processing Fatty Specimens Webinars (Knowledge Pathway)The Cost of Reprocessing Webinars (Knowledge Pathway)Why are Automation & Innovation Critical to the Histology Lab?