Image Image Exceptionally precise stepper motor promotes the production of high quality sections of consistent thickness. Leica CM3050 S Cryostat Processing multiple specimen and performing serial cuts can result in high section numbers. Nevertheless, reproducibility can't be compromised. Permanent attention to detail and many hours in front of the cryostat can be exhausting for the user. The Leica CM3050 S cryostat is designed to help with exactly these time-consuming jobs. The low working height and available knee space of the Leica CM3050 S cryostat allow the user to work comfortably while sitting. Motorized drive and section counter improve productivity for multiple serial sections. Particularly when working with delicate specimens, e.g. brain samples, the precise specimen orientation and the specimen feed system provide for reproducible sections. Contact us to get a quote. Call 00 308 321 0320 to speak with a representative. Specifications Features Downloads Parts/Accessories Technical Specifications GENERAL Width: 882 mm Depth: 766 mm Height: 1040 mm Weight (incl. microtome): approx. 180 kg Temperature setting range: 0°C to -40°C Maximum specimen size: 40 x 55 mm Cutting speed: 0.1 mm/s to 170 mm/s 0.1 mm/s to 100 mm/s Vmax: 210 mm/s Section thickness setting 0.5 to 300 μm Maximum specimen size 40 mm x 55 mm Horizontal specimen feed 25 mm Vertical specimen stroke 59 mm Specimen retraction 50 pm Specimen precision orientation by 8° (x/y/z axis) Trimming 5 to 150 μm ± 0,5 μm in steps of 5, 10, 30, 50, 100 and 150 μm Motorized coarse feed at two speeds 500 μm/s and 1,000 μm/s Cutting speed ranges 0.1 mm/s to 170 mm/s, 0.1 mm/s to 100 mm/s, Vmax 210 mm/s Temperature setting range 0°C to -40°C Defrosting programmable 1 automatic defrost cycle/24 h duration; from 6 to 12 min; manual defrosting Freezing shelf temperature Approx. -43°C at an ambient temperature of 22°C Temperature setting range -10°C to -50°C (+/-3 K) Dimensions (W x H x D) 882 x 1040 x 766 mm Weight (including microtome) Approx. 180 kg Power draw 1800 VA Product Features Precision Sectioning When working with large samples, accurate specimen orientation and feed are crucial. The precise specimen orientation system with zero position provides for x/y adjustment of up to 8°. The specimen feed system with 25mm horizontal feed allows for reproducible thin sections. Image Precision Cooling An independent refrigeration system for the object head provides for temperature changes and efficient specimen temperature control to adjust for difficult samples such as brain or fatty tissue. Highly efficient insulating materials and a dedicated cooling system support stable cryochamber temperatures, even when producing serial sections all day long. Image Stay Organized With critical items at hand, you can focus on your sectioning job. Freezing stage and tool tray in a large cryochamber, as well as an easily accessible storage area on top of the cryostat help you staying organized. The motor drive with foot-pedal enables you to have both hands free for sample handling. Image Stay Focused Section thickness totalizer and counter with reset button facilitate target preparation and promote fast trimming between levels. With the reverse section counter, a preselected number of sections can be carried out in both sectioning and trimming mode. Image Comfortable Sitting Position The Leica CM3050 S cryostat with its low working height and available knee space allows the user to work comfortably while sitting. The optional electrohydraulic height adjustment grants tall users an adjustable working height and even more knee space. For users who prefer standing when sectioning, the height adjustment can lift the instrument up to standing working height. Image Downloads Brochure Brochure - Leica CM3050 S Cryostat - PT (210137 Rev A) Size: 999.5 KB, Type: pdf Brochure - Leica CM3050 S Cryostat - ZH (210138 Rev A) Size: 1.05 MB, Type: pdf Brochure - Leica CM3050 S Cryostat - JP (210139 Rev A) Size: 1.05 MB, Type: pdf Brochure - Leica CM3050 S Cryostat - EN (95.8846 Rev E) Size: 520.31 KB, Type: pdf Brochure - Leica CM3050 S Cryostat - DE (95.8847 Rev E) Size: 1003.62 KB, Type: pdf Brochure - Leica CM3050 S Cryostat - Fr (95.8848 Rev E) Size: 999.97 KB, Type: pdf Brochure - Leica CM3050 S Cryostat - ES (95.8849 Rev E) Size: 999.11 KB, Type: pdf Brochure - Leica CM3050 S Cryostat - IT (95.8850 Rev E) Size: 997.7 KB, Type: pdf Certificate DoC Leica CM3050 S B Size: 371.79 KB, Type: pdf SDS Cryostat oil Typ Isoflex PDP 38 2015-04-02 10695-0007 CHN-zh Size: 258.38 KB, Type: pdf Cryostat oil Typ Isoflex PDP 38 2015-04-02 10695-0007 D-de Size: 77.8 KB, Type: pdf Cryostat oil Typ Isoflex PDP 38 50ml 14033606098 Rev.01 GB Size: 77.27 KB, Type: pdf Kühlöl Typ Isoflex PDP 38 E-es 10695-0007 1 0 Size: 75.82 KB, Type: pdf Kühlöl Typ Isoflex PDP 38 F-fr 10695-0007 1 0 Size: 77.39 KB, Type: pdf Kühlöl Typ Isoflex PDP 38 I-it 10695-0007 1 0 Size: 75.31 KB, Type: pdf IFU 14044380117P CM3050S IFU 2v6P cs Size: 4.01 MB, Type: pdf 14044380103P CM3050S IFU 2v6P da Size: 4 MB, Type: pdf 14044380100P CM3050S IFU 2v6P de Size: 4.02 MB, Type: pdf 14044380101P CM3050S IFU 2v6P en Size: 3.99 MB, Type: pdf 14044380116P CM3050S IFU 2v6P es Size: 4.03 MB, Type: pdf 14044380105P CM3050S IFU 2v6P fr Size: 4.05 MB, Type: pdf 14044380104P CM3050S IFU 2v6P fi Size: 4 MB, Type: pdf 14044380107P CM3050S IFU 2v6P it Size: 4.04 MB, Type: pdf Leica CM3050S IFU 2v6P nl Size: 3.4 MB, Type: pdf 14044385108P CM3050S IFU 2v6P ja Size: 3.25 MB, Type: pdf 14044380138P CM3050S IFU 2v6P kk Size: 4.11 MB, Type: pdf 14044380130P CM3050S IFU 2v6P ko Size: 4.34 MB, Type: pdf 14044380112P CM3050S IFU 2v6P pt Size: 4.02 MB, Type: pdf 14044380113P CM3050S IFU 2v6P ru Size: 4.07 MB, Type: pdf 14044380114P CM3050S IFU 2v6P sv Size: 4 MB, Type: pdf 14044389102P CM3050S IFU 2v6P zh Size: 4.61 MB, Type: pdf Leica MH 2v3C bg Size: 297.58 KB, Type: pdf Leica MH 2v3C cs Size: 290.53 KB, Type: pdf Leica MH 2v3C da Size: 280.99 KB, Type: pdf Leica MH 2v3C de Size: 283.26 KB, Type: pdf Leica MH 2v3C el Size: 279.85 KB, Type: pdf Leica MH 2v3C en Size: 292.86 KB, Type: pdf Leica MH 2v3C es Size: 283.89 KB, Type: pdf Leica MH 2v3C fr Size: 285.5 KB, Type: pdf Leica MH 2v3C hr Size: 286.71 KB, Type: pdf Leica MH 2v3C hu Size: 288.6 KB, Type: pdf Leica MH 2v3C it Size: 282.42 KB, Type: pdf Leica MH 2v3C ja Size: 520.62 KB, Type: pdf Leica MH 2v3C lt Size: 275.78 KB, Type: pdf Leica MH 2v3C nl Size: 279.14 KB, Type: pdf Leica MH 2v3C no Size: 280.01 KB, Type: pdf Leica MH 2v3C pl Size: 282.6 KB, Type: pdf Leica MH 2v3C pt Size: 283.72 KB, Type: pdf Leica MH 2v3C ro Size: 286.05 KB, Type: pdf Leica MH 2v3C ru Size: 286.86 KB, Type: pdf Leica MH 2v3C sk Size: 275.12 KB, Type: pdf Leica MH 2v3C sr Size: 273.28 KB, Type: pdf Leica MH 2v3C sv Size: 281.67 KB, Type: pdf Leica MH 2v3C tr Size: 276.29 KB, Type: pdf Leica MH 2v3C zh Size: 738.9 KB, Type: pdf Leica CM3050 S Parts/Accessories View all Leica CM3050 S Parts/Accessories Education Editorial (Knowledge Pathway)Freezing Biological Samples Tutorials (Knowledge Pathway)The Art of Frozen Tissue Sectioning