Image BOND RX provides consistent, high-quality stains so you know vital information is always clearly visible Image Find Breakthroughs Faster with BOND RX Image Access antibodies, probes and detection systems at any time for flexible test management. Image View bulk reagent levels and status changes at a glance with BOND RX’s unique active lighting system. Image Give users the ability to quickly load slides on three independent trays Image Take advantage of an easy-to-use interface with a workflow and terminology specifically designed for research. Image Enable fast, fully automated multiplexing studies BOND RX Fully Automated Research Stainer 21.2821 Find Breakthroughs Faster with the Freedom to Discover Speed up your next big discovery. Use the BOND RX to confidently complete IHC, ISH, FISH, CTC, multiplexing and other tests. Explore your ideas in a variety of ways via open reagents, open detection kits, and customizable protocols. The BOND RX provides an easy way for labs to fully automate tests and accelerate research programs. Accelerate test programs through speed, efficiency, and consistent automation, reducing manual work so that researchers can spend less time at the bench and more time innovating. Preserve morphology and integrity of precious tissue with the unique Covertile system that allows you to dispense reagents in a highly-controlled and more consistent manner. 91% of customers find the stain quality and reproducibility to be better than the competition.* Commercialize your discovery with a clear path from research to clinical applications, and leverage greater access to innovative emerging technologies via partnerships. Contact us to get a quote. Call +65 6335 3526 to speak with a representative. For Research Use Only. Not for use in diagnostic procedures. *Independent Surveys Features MULTIPLEX Innovations/Partnerships Specifications Reagents/Consumables Downloads Resources Publications Product Features Flexible Protocols Help Turn Theories Into Action BOND RX lets researchers fully automate emerging technologies (including new molecular applications), customize all protocol segments and put theories into action. Preparation - Customize your baking and dewax options. Antigen Retrieval - Change Incubation time and temperature as desired. ISH Probes – Leverage new probe application and removal options. Staining – Choose your incubation times, temperatures, dispense types and more. Image Get Started Right Away BOND RX makes it easy to run the unique reagents you’re working with and quickly automate innovative tests. In fact, you can simply pipette directly into open containers to get your antibody or probe onto the BOND RX. Create your own detection kits using simple and efficient research detection kits. Fully automate staining with extremely small volumes of high value reagents using Titration containers. Image Do More in Less Time with BOND RX BOND RX helps research labs work more efficiently because it streamlines the test management process and makes it more flexible. Save time by having antibodies, probes and detection systems accessible at any time. Eliminate mundane tasks and minimize maintenance. Reduce user strain with low-weight containers that are easy to handle. View bulk reagent levels at a glance with a unique active lighting system. Image Be Confident In Results With Proprietary Covertile Technology The BOND Covertile protects tissue morphology and enables gentle and consistent reagent application, unlike competitors who may not use a Covertile at all, or not for all steps of the process. Image Commercialize Your Discovery You gain tools to customize protocols and streamline the transition to clinical. The shared core technology provides you with a clear path from research to clinical. Fully Transparent Operations Researchers are in full control with BOND RX. It provides the insight you need to have a complete understanding of each test. You can view reagent application, monitor protocol progress, receive comprehensive reports and more. BOND RX Software 7.0 BOND RX 7.0 software supports enhanced chromogenic and fluorescent multiplexing functionality by allowing up to 6 individual markers to be visualized on a single slide. Break Through the Staining Barrier The more markers per slide, the more opportunities to get to your discovery endpoint faster, all while using less precious tissue. Maximize the data you can achieve per sample via fully customized protocols from deparaffinization to counterstain and all the steps in between. Unlock cellular secrets through multiplexing to visualize multiple targets on a single slide Discover the next breakthrough assay by designing your custom detection system and ideal protocol Image Unlock Cellular Secrets Multiplex on your research BOND stainer to Discover spatial relationships Determine cellular phenotypes Maximize the data from a single tissue sample Supported by a wide range of technology partnerships Image Design the Next Breakthrough Assay Freedom to Discover Stain up to 6 markers DNA to RNA to protein FFPE and CTCs Chromogenic, Fluorescent and Sequencing Image Explore the Color Options Choose up to 6 chromogens per slide; plug-and-play or choose your own. Let the instrument do the mixing with chromogens specifically designed for BOND stainers. With our plug-and-play chromogens, just scan and load on the BOND instrument. DAB Fast Red Green Blue Image Tailor to Your Target BOND RX Software 7.0 provides the flexibility to design your ideal protocol Select up to 6 markers per slide Create your own detection systems Fully customize all your research protocols Change time, temperature and dispense type Image Access the Latest Research Advances Leica Biosystems partners with a range of Open Innovation (OI) partners. As a result, you have many flexible solutions for your research. All protocols and protocol templates developed in conjunction with our OI partners are available on BOND RX and BOND RXm so you can access the latest research advances in the shortest time. A Fully Integrated RNA ISH Solution Partner - ACD Complete up to 30 slides in a single 11-hour run for single plex (and a 14-hour run for duplex) with high-throughput staining. This solution is: Highly specific – Amplifies signals using double z probe strategy and simultaneous background suppression strategy to ensure target-specific binding. Sensitive & Quantitative – Detects single RNA molecules at single cell resolution. Morphological – Provides cell specific expression in information intact tissue architecture. Universal – Use for virtually any gene, species or tissue. Watch the Partnership Video - ACD RNAscope X Image Multiplex Staining With No Intervention Partner – Akoya* Free up researchers’ time by creating beautiful, seven-color immunofluorescence slides without any intervention. Up to 30 slides can be created in about 14 hours. Visualize up to six tissue biomarkers at the same time plus a nuclear counterstain. Use the best primary antibodies – regardless of species – with no crosstalk. Optimize the editable protocol with ease so it meets your specific needs. *Previously PerkinElmer Image Brilliant, Rapid, Chromogenic Multiplex IHC Partner - Cell IDx UltraPlex multiplex chromogenic staining technology is simple, fast and fully automated allowing you to go from staining to analysis in a single day. Generate beautiful images and data on biomarker expression and spatial localization of cell subtypes using the BOND RX System and Aperio Scanners. UltraPlex technology allows the automated detection of multiple markers on BOND RX staining system using primary antibodies from any species, while employing a single antigen retrieval step 3 marker/chromogen stain in 4.5 hours 4 marker/chromogen stain in 6 hours Optimized staining panels of key biomarkers for FFPE tissue Chromogenic detection of cell subtypes coexpressing biomarkers using optimized chromogen combinations Image High Plex, Spatial Profiling of Proteins and RNA from FFPE Partner – NanoString Combining standard immunofluorescence techniques with digital optical barcoding technology, the GeoMx™ Digital Spatial Profiler enables high plex, spatially-resolved profiling of protein and RNA. The GeoMx Assays allow for imaging and profiling from a single FFPE or fresh frozen tissue section. Quantify up to 96 proteins and over 1000 RNA targets with spatial context Focus on rare cells or compartment specific regions of interest in tissue Preserve precious samples with non-destructive processing Image CTC Analysis For Experimental Pathology Labs Partner - Rarecyte The AccuCyte-Cytefinder system integrates with the BOND RX and provides microscopic visualization of circulating tumor cells. It delivers single cell retrieval of taprget cells for downstream genomic analysis. AccuCyte collects nucleated cells including circulating tumor cells from whole blood. CyteSealer makes collection seamless by creating a barrier between the buffycoat and red blood cells. CyteSpreader ensures the precise amount of nucleated cells is spread onto each slide every time. Image Single Step Multiplexing, Fully Automated Partner - Ultivue Create up to 30, five color, single step multiplexing slides in under 6 hours hours on BOND RX whilst preserving tissue morphology and integrity. Spend less time perfecting difficult manual techniques and more time focusing on your next research breakthrough. Survey and analyse cell phenotypes with spatial context within the tumor microenvironment though high performance tissue-based biomarker multiplex assays Multiplex on a single slide, using a single antibody cocktail and incubation step, powered by DNAbarcoded antibodies with unique, complementary, fluorescent DNA barcodes Preserve sample integrity for additional analyses without damaging tissue or cross talk Image and analyse with Aperio VERSA and Aperio Cellular IF Algorithm Image Product Specifications DIMENSIONS & WEIGHT Dimensions (W x H x D): 790 mm x 1378 mm x 806 mm (31.1 x 54.25 x 31.73 in) Weight (Dry): 238 kg (525 lbs) ELECTRICAL Operating Voltage (older-model power supply; one fan in back cover): 103.4 V to 127.2 V (for nominal voltage 110 V to 120 V) Power Consumption: 1200 VA Operating Voltage (newer-model power supply; two fans in back cover): 90 V to 264 V (for nominal voltage 100 V to 240 V) Mains Frequency: 50/60 Hz ENVIRONMENTAL (UNPACKED INSTRUMENTS) Maximum Operating Temperature: 35°C (95°F) Minimum Operating Temperature: 5°C (41°F) Temperature Required to meet Staining Performance Requirements: 18–26°C (64–79°F) Maximum Heating Energy Output: 1200W/1000W Operating Humidity (Non-Condensing): 30 to 80% RH Maximum Operating Altitude: 0 to 1600 m (5250 ft.) above sea level Sound Pressure Level Output (at 1 m): < 85 dBA maximum < 65 dBA normal operation OPERATING Slide Capacity: 30 Finished trays (10 slides) may be replaced continuously Number of Reagent Containers: 36 Reagent Container Capacity: 7 mL and 30 mL Titration Container Capacity: 6 mL Bulk Reagent Container Capacity: 2 L or 5 L Hazardous Waste Container Capacity: 5 L Standard Waste Container Capacity: 2 x 5 L Chemical Compatibility: All BOND Reagents 70% Alcohol Solution (for cleaning purposes) Temperature Indication: Defaults (these can be changed by service representatives): Warm: 35°C, Hot: 80°C Maximum permitted pressure for gas and liquid connections: 1.0 bar MICROSCOPE SLIDES Slide Width: 24.64–26.0 mm (0.97–1.02 in) Slide Length: 74.9–76.0 mm (2.95–2.99 in) Slide Thickness: 0.8–1.3 mm (0.03–0.05 in) Label Area Width: 24.64–26.0 mm (0.97–1.02 in) Label Area Length: 16.9–21.0 mm (0.67–0.83 in) Material: Glass, ISO 8037/1 TRANSPORT AND STORAGE (PACKED INSTRUMENTS) Storage Temperature: -20 to 55 °C (-4 to 131 °F) Storage Humidity (Non-Condensing): < 80% RH Shipping Methods: Road and Air Freight Compatible Novocastra HD Antibodies Deliver Higher Optimal Staining Rates Compared to Leading Vendors To deliver the performance you demand, our Novocastra HD line is independently evaluated by external quality assurance organization NordiQC. Head-to-head comparisons against other leading vendors show that our antibodies consistently deliver superior staining quality. Novocastra HD Range Complete Novocastra Primary Antibody Online Catalog Download our print catalog Image Exceptional Sensitivity for Exceptional Detection with Compact Polymer Technology Lean efficiency – full automation reduces waste and process variation Complete system – all aspects of the system optimized to work together to support your entire process Downloads BOND RTU Antibody and Protocol Data Files BOND-RX-Ext-v36-04 07 08-580-Canada Size: 3.04 MB, Type: bxd BOND-RX-Ext-v36-04 07 08-580-Europe Size: 2.99 MB, Type: bxd BOND-RX-Ext-v36-04 07 08-580-Japan Size: 2.99 MB, Type: bxd BOND-RX-Ext-v36-04 07 08-580-RestOfWorld Size: 2.99 MB, Type: bxd BOND-RX-Ext-v36-04 07 08-580-US Size: 3.03 MB, Type: bxd Brochure Brochure - Ultivue + BOND RX EN (181056 Rev B) Size: 1.74 MB, Type: pdf Brochure - BOND RX EN (190705 Rev A) Size: 2.44 MB, Type: pdf Brochure - BOND RX DE (201166 Rev A) Size: 11.01 MB, Type: pdf Brochure - BOND RX ES (201166 Rev A) Size: 11.05 MB, Type: pdf Brochure - BOND RX FR (201166 Rev A) Size: 11.06 MB, Type: pdf Brochure - BOND RX IT (201166 Rev A) Size: 11.04 MB, Type: pdf Brochure - BOND RX EN (201166 Rev B) Size: 2.4 MB, Type: pdf Brochure - BOND RX KR (201166 Rev A) Size: 2.41 MB, Type: pdf Brochure - BOND RX PT (201166 Rev A) Size: 11.03 MB, Type: pdf Brochure - BOND RX ZH (201166 Rev A) Size: 11.18 MB, Type: pdf Brochure - BOND RX JP (201166 Rev B) Size: 11.12 MB, Type: pdf Flyer - BOND Variants (95.14081 Rev C) Size: 270.01 KB, Type: pdf Brochure - ACD RNAscope + BOND RX (95.13243 Rev A) Size: 659.12 KB, Type: pdf Flyer - BOND Covertile - Infographic (95.12688 Rev C) Size: 170.95 KB, Type: pdf Brochure - Perkin Elmer BOND RX (95.14592 Rev B) Size: 732.87 KB, Type: pdf Brochure - RareCyte + BOND RX (95.13660 Rev A) Size: 690.89 KB, Type: pdf Certificate DHFR 9812 A05 BOND RX CE Declaration of Conformity Size: 745.64 KB, Type: pdf Resources BOND RTU Antibody and Protocol Data Files These data files will enable the use of the latest protocol releases for BOND RX/RXm. Local licensing restrictions may apply to some products; please contact your local Leica Biosystems Sales or Support representative should you have any queries. Please ensure the correct data file is downloaded. Important Notes Do not apply this update to BOND-III or BOND-MAX Systems. Please download and apply the correct update is for your region. We recommend that all BOND systems be updated to the latest software version - BOND RX research software v7.0 BOND RX research software v7.0 requires BXD v25 or above Do not apply this update to Systems running RX/RXm v4.0 software; this file is not applicable to software v4.0 Systems. Data Files: Download the BOND-RX-Ext-v36-04_07_08-580-US data file here. Download the BOND-RX-Ext-v36-04_07_08-580-Canada data file here. Download the BOND-RX-Ext-v36-04_07_08-580-Europe data file here. Download the BOND-RX-Ext-v36-04_07_08-580-Japan data file here. Download the BOND-RX-Ext-v36-04_07_08-580-RestOfWorld data file here. Videos X Partnership - ACD RNAscope: From Manual Research to Fully Automated Clinical Platform X Covertile System – Reagent Application Virtual Demo BOND RX Publications View all BOND RX Publications Education Training Resources (Knowledge Pathway)Immunohistochemistry: An Overview + Steps to Better IHC Staining