Image Image Image Image Image BOND-PRIME Fully Automated and Adaptable, High-Speed IHC, and ISH Staining Platform 91.0021 High productivity through Speed, Quality, and Universal Access The BOND-PRIME staining platform delivers high productivity, featuring Universal Access, and can seamlessly adapt to your incoming workflow demands – whether it be batch, continuous, single slide or STAT cases, or a combination of all the above. Coupled with the ability to produce high-quality, crisp, clear staining with an average IHC slide TAT of 95 minutes, the BOND-PRIME staining platform lets you transcend expectations for quality, timeliness, and diagnostic productivity. Contact us to get a quote. Call +44 800 011 9620 to speak with a representative. For In Vitro Diagnostic Use Features Specifications REAGENTS/CONSUMABLES Downloads Resources Product Features Load Any Slide in Any Combination, with Any Reagent, at Any Time with Universal Access on BOND-PRIME Load Any Slide – Independent Active Reagent Control (ARC) Modules are precisely engineered, individual staining chambers that enable you to run any combination of staining protocols, pretreatments, chromogens, and technologies. In Any Combination – The BOND-PRIME stainer continually adapts to incoming work so you can load single slides, complete cases, full batches, or any workflow to keep your slides processing. With Any Reagent – Featuring 70 open-access reagent positions, ample reagent space means no delays to add antibodies and/or detection. Fill and empty bulk containers less often with an over 200 slide bulk reagent capacity. At Any Time – Process up to 48 slides seamlessly. Load slides in the Preload Drawer even when at staining capacity and unload slides when you are ready since finished slides don’t prevent the staining of new slides. Image Shorten the TAT from request to diagnosis The BOND-PRIME staining platform has unprecedented speed achieving the breakthrough milestone average IHC slide TAT of 95 min. The average IHC TAT for a 24-slide batch is <130 minutes and as fast as one hour for single/STAT slides. Featuring next-generation robotics, optimized staining protocols with premium reagents, and innovative Active Reagent Control technology, you don’t have to compromise quality for speed. IHC testing is often the precursor to additional, more complex testing, so rapid results mean expedited diagnostic information to provide clarity to treatment. With so much relying on this testing, getting to the diagnosis faster is paramount. Image Crisp, clear stains with the details pathologists look for The progressive automation on the BOND-PRIME instrument works in tandem with our premium reagents to produce crisp, clear, high-quality staining in 95 minutes. Active Reagent Control (ARC) technology – Consistent and reproducible staining with highly controlled dispense, reagent flow, and precise incubation to each and every slide. Premium staining reagents – Distinctive Novocastra advanced staining reagents and detection chemistry featuring Covertile technology achieve next-level staining. ARC Covertile – Semi-permanent, self-cleaning ARC Covertile provides a sealed staining environment that protects tissue morphology, uses minimal reagents, and provides total tissue care. Because competing in today’s diagnostic world requires quality diagnosis AND fast TAT. Image High productivity through Speed, Quality, and Universal Access The adaptable workflow, unprecedented speed, and excellent staining quality from the BOND-PRIME instrument delivers enhanced diagnostic productivity for an efficient and confident diagnosis. Speed – Featuring a 95-minute average turnaround time for continuous workflow, individual slides as fast as 1 hour, and less than 130 minutes for a full 24-slide load; BOND-PRIME enables pathologists to deliver a timely diagnosis to patients who need answers quickly. Quality – The BOND-PRIME staining platform delivers vibrant, crisp, clear stains to provide diagnostic clarity. Excellent staining quality helps you use your time and expertise effectively for a confident and timely diagnosis. Universal Access – Universal Access enables a fully adaptable workflow, decreasing the time to load and stain slides which equates to less time waiting for completed cases. Image Product Specifications BOND-PRIME System Specifications Dimensions: 1217 mm (W) x 1400 mm (H) x 829 mm (D) 47.9 in (W) x 55.1 in (H) x 32.6 in (D) Slide capacity: 72 (24 slides in Preload Drawer, 24 slides in ARC Array, 24 slides in Unload Drawer) Number of reagent containers: 70 Hazardous waste container capacity: 4.5 L Operating voltage and Mains frequency: 90 V to 264 V (for nominal voltage 100 V to 240 V) Sound pressure level output (at 1 m): < 85 dBA maximum < 65 dBA normal operation Weight (Dry): 384 kg (847 lb) Reagent container capacity: 7 mL, 30 mL, and 6 mL Titration vials/inserts Bulk reagent container capacity: 1.25 L or 4.5 L for DI Water External bulk waste container capacity: 4.5 L Power Consumption: 1260 VA Microscope Slide Specifications Slide Width: 24.64–26.0 mm (0.97–1.02 in) Slide Length: 74.9–76.0 mm (2.95–2.99 in) Slide Thickness: 0.9–1.2 mm (0.03–0.05 in) Label Width: 24.64–26.0 mm (0.97–1.02 in) Label Length: 16.9–21.0 mm (0.67–0.83 in) Material: Glass, ISO 8037/1 BOND-PRIME Detection Systems Our BOND-PRIME Detection Systems feature our Compact Polymer technology to provide crisp, clear, high-quality staining. Hematoxylin is sold separately. BOND-PRIME Polymer DAB Detection System (DS9284) BOND-PRIME Polymer AP Detection System (DS9304) BOND-PRIME Hematoxylin (AR0096) A range of BOND ready-to-use primary antibodies are available. BOND-PRIME Ancillary Reagents BOND-PRIME Dewax Solution (AR0084) BOND-PRIME Wash Solution Concentrate (AR0085) BOND-PRIME Epitope Retrieval Solution 1 (AR0086) BOND-PRIME Epitope Retrieval Solution 2 (AR0087) BOND-PRIME Consumables BOND-PRIME Cleaning Kit (CS9300) BOND-PRIME ARC Refresh Kit (91.1592) View All BOND-PRIME REAGENTS & CONSUMABLES Downloads Brochure Brochure – BOND-PRIME (220100 Rev D) Size: 21.86 MB, Type: pdf Brochure – BOND-PRIME DE (220100 Rev B) Size: 1.67 MB, Type: pdf Brochure – BOND-PRIME ES (220100 Rev B) Size: 1.65 MB, Type: pdf Brochure – BOND-PRIME FR (220100 Rev B) Size: 23.75 MB, Type: pdf Brochure – BOND-PRIME IT (220100 Rev B) Size: 2.15 MB, Type: pdf Brochure – BOND-PRIME PT (220100 Rev B) Size: 23.9 MB, Type: pdf Flyer Flyer – BOND Portfolio (220276 Rev C) Size: 429.82 KB, Type: pdf BOND RTU Antibody and Protocol Data Files BOND-Ext-v111-01 06 08-591-US Size: 2.29 MB, Type: bdd BOND-Ext-v111-01 06 08-591-Canada Size: 2.28 MB, Type: bdd BOND-Ext-v111-01 06 08-591-RestOfWorld Size: 2.29 MB, Type: bdd BOND-Ext-v111-01 06 08-591-Europe Size: 2.21 MB, Type: bdd BOND-Ext-v111-01 06 08-591-Japan Size: 2.26 MB, Type: bdd Certificate DHFR 14804 A03 BOND-PRIME IVDR Declaration of Conformity Size: 638.23 KB, Type: pdf IFU 91.7500.507 A09 Brugermanual til BOND-PRIME da-DK Size: 44.46 MB, Type: pdf 91.7500.508 A09 Gebruikershandleiding BOND-PRIME nl-NL Size: 46.12 MB, Type: pdf 91.7500.509 A09 BOND-PRIME Käyttöopas fi-FI Size: 45.73 MB, Type: pdf 91.7500.510 A09 Manuel d'utilisation BOND-PRIME fr-FR Size: 44.75 MB, Type: pdf 91.7500.511 A09 BOND-PRIME Benutzerhandbuch de-DE Size: 44.72 MB, Type: pdf 91.7500.512 A09 Εγχειρίδιο χρήσης BOND-PRIME el-GR Size: 45.95 MB, Type: pdf 91.7500.515 A09 Manuale dell’utente BOND-PRIME it-IT Size: 44.5 MB, Type: pdf 91.7500.521 A09 Manual do Utilizador do BOND-PRIME pt-PT Size: 44.84 MB, Type: pdf 91.7500.525 A09 Manual del usuario de BOND-PRIME es-ES Size: 44.62 MB, Type: pdf 91.7500.526 A09 BOND-PRIME Användarmanual sv-SE Size: 44.21 MB, Type: pdf 91.7500.501 A09 BOND-PRIME User Manual en-US Size: 45.74 MB, Type: pdf 91.7500.519 A09 BOND-PRIME brukerhåndbok nb-NO Size: 46.08 MB, Type: pdf 91.7500.529 A09 Manual do usuário BOND-PRIME pt-BR Size: 45.71 MB, Type: pdf 91.7500.530 A09 BOND-PRIME Kullanım Kılavuzu tr-TR Size: 45.22 MB, Type: pdf 91.7500.516 A09 BOND-PRIME ユーザーマニュアル ja-JP Size: 46.85 MB, Type: pdf 91.7500.517 A09 BOND-PRIME 사용 설명서 ko-KR Size: 45.63 MB, Type: pdf Quick Tips 91.7506.501 A07 bond prime quick tips en-US Size: 9.09 MB, Type: pdf 91.7506.507 A07 bond prime Hurtige tips da-DK Size: 9.15 MB, Type: pdf 91.7506.508 A07 bond prime Snelle tips nl-NL Size: 9.01 MB, Type: pdf 91.7506.509 A07 BOND-PRIME-pikaohjeet fi-FI Size: 9.01 MB, Type: pdf 91.7506.510 A07 Conseils pratiques sur l’utilisation du BOND-PRIME fr-FR Size: 9.26 MB, Type: pdf 91.7506.511 A07 bond prime Kurztipps de-DE Size: 9.28 MB, Type: pdf 91.7506.512 A07 bond prime Σύντομες συμβουλές el-GR Size: 9.64 MB, Type: pdf 91.7506.515 A07 Suggerimenti rapidi su bond prime it-IT Size: 9.24 MB, Type: pdf 91.7506.519 A07 bond prime hurtigtips nb-NO Size: 9.03 MB, Type: pdf 91.7506.521 A07 Dicas rápidas bond prime pt-PT Size: 9.28 MB, Type: pdf 91.7506.525 A07 Consejos rápidos de bond prime es-ES Size: 9.27 MB, Type: pdf 91.7506.526 A07 Snabbtips för bond prime sv-SE Size: 9.2 MB, Type: pdf 91.7506 516.A07 bond prime quick tips ja-JP Size: 9.6 MB, Type: pdf 91.7506.517 A07 bond prime quick tips ko-KR Size: 9.42 MB, Type: pdf 91.7506.530 A07 bond prime quick tips tr-TR Size: 9.41 MB, Type: pdf BOND-PRIME Launch - Watch on Demand Immunohistochemistry PRIME TIME Keynote & Welcome We have a history of innovation to address customer needs. From ensuring urgent cases are processed efficiently, to decreasing the number of cases left pending, our new IHC stainer presents a quantifiable to mid-sized and large laboratories. Presenter: Gustavo Perez-Fernandez President - Leica Biosystems X Get Ready for PRIME TIME - Unveiling the Next Generation IHC & ISH Stainer Introducing our new BOND-PRIME platform and how this innovative solution can add value to a laboratory. Presenters: James Anderson - Sr. Global Product Manager - Advanced Staining-Leica Biosystems Kellie Madigan - Principle Scientist - Leica Biosystems X Key Challenges for the Immunohistochemistry Lab With IHC turnaround time shortened to an average 90 mins slide TAT, and 100% instrument utilization without constant attention, this next generation stainer's impact on workflow is truly impressive. Presenter: Dr. David Ferber - Sr. Medical Science Liaison Leica Biosystems X Crisp, Clear Slides - How the Next Generation Core Technology is Meeting Pathologists Quality Needs Highlighting Leica Biosystems' understanding of the importance of a quality diagnostic slide and how the new BOND-PRIME core technology delivers on this need. Presenter: Kellie Madigan - Principle Scientist - Leica Biosystems X Technical Team answering your questions Presenters: James Anderson - Sr. Global Product Manager - Advanced Staining-Leica Biosystems Kellie Madigan - Principle Scientist - Leica Biosystems X Education Related Products BOND-ADVANCE Advanced IHC and ISH NetworkLEARN MORE BOND-MAX Fully Automated IHC and ISH Staining SystemLEARN MORE CEREBRO Workflow Management SystemLEARN MORE BOND-III Fully Automated IHC and ISH Staining SystemLEARN MORE